PrepMaster Digital
Log in

CRCST Chapter 5 Quiz (9th Edition): 20 Free Questions

Published 2026-11-08 · Facts and text checked 2026-11-02 · Questions from our CRCST study guide · Reviewed by Hana N., Quality Reviewer

This free quiz has 20 questions on the topics of chapter 5, Infection Prevention, of the HSPA Sterile Processing Technical Manual, 9th edition: infection prevention, transmission and protective equipment. They are our own questions, from our CRCST study guide, not taken from the manual. Click an answer to read the explanation.

Our own questions on the topics of chapter 5, Infection Prevention, of the HSPA Sterile Processing Technical Manual, 9th edition. On the exam this is part of Cleaning, Decontamination and Disinfection. Open each answer to read the explanation.

Question 1Medium

When instruments are received in the decontamination area from a patient with suspected transmissible spongiform encephalopathy (TSE), what is the immediate action required?

Show answer and explanation

Correct answer: D. Quarantine the instruments until the specific prion inactivation protocol can be performed

Instruments from suspected TSE cases must be quarantined until the recommended prion inactivation protocol (e.g., NaOH or prolonged autoclaving) is completed. Standard processing (A) is not sufficient; sporicidal agents (B) may not inactivate prions; discarding (C) is not necessary if reprocessing is possible.

From practice test 6 of our CRCST study guide (question 55). Original question, not an official exam item.

Question 2Medium

A flexible colonoscope used only on intact mucous membranes is being reprocessed. What is the minimum level of reprocessing?

Show answer and explanation

Correct answer: C. High-level disinfection

A flexible colonoscope is a semi-critical item contacting intact mucous membranes, so high-level disinfection is appropriate. Sterilization is not required but is acceptable.

From practice test 6 of our CRCST study guide (question 117). Original question, not an official exam item.

Question 3Easy

Immediately after a needlestick injury, what is the first step the technician should take?

Show answer and explanation

Correct answer: C. Wash the wound with soap and water and report the injury

The recommended protocol for needlestick injury is to wash the wound thoroughly with soap and water and report the incident immediately. Squeezing is not recommended, and disinfection alone is inadequate.

From practice test 4 of our CRCST study guide (question 28). Original question, not an official exam item.

Question 4Easy

When donning a sterile gown, which action is correct regarding the use of gloved hands?

Show answer and explanation

Correct answer: B. Use gloved hands to position the sleeves and fasten the ties

During sterile gowning, the gown's front and sleeves are sterile. Gloved hands should only touch sterile areas; thus they are used to position sleeves and fasten ties. The inside of the gown is not sterile, and ties at the back are not touched by gloved hands.

From practice test 4 of our CRCST study guide (question 9). Original question, not an official exam item.

Question 5Easy

In the chain of infection model, which link is directly interrupted by proper hand hygiene before and after patient contact?

Show answer and explanation

Correct answer: A. Portal of exit and mode of transmission

Hand hygiene removes pathogens from hands, thereby blocking the portal of exit (hands) and the mode of transmission (contact). It does not affect the host's susceptibility or the infectious agent itself.

From practice test 3 of our CRCST study guide (question 68). Original question, not an official exam item.

Question 6Medium

A central service technician is processing instruments from a patient known to have hepatitis B. According to standard precautions, how should these instruments be handled?

Show answer and explanation

Correct answer: C. They are processed exactly the same as instruments from any other patient

Standard precautions apply to all patients regardless of diagnosis, meaning the same reprocessing procedures (cleaning, disinfection, sterilization) are used for every patient. Special handling based on known infection (A) is not part of standard precautions; instead, treat all blood and body fluids as potentially infectious.

From practice test 3 of our CRCST study guide (question 14). Original question, not an official exam item.

Question 7Medium

A surgical instrument used on a patient with suspected Creutzfeldt-Jakob disease requires special processing. Which of the following protocols is appropriate?

Show answer and explanation

Correct answer: D. Exposure to 1N sodium hydroxide or autoclaving at 134°C for 18 minutes

Prions require either prolonged exposure to 1N sodium hydroxide or autoclaving at 134°C for at least 18 minutes to be inactivated. Standard sterilization is insufficient.

From practice test 6 of our CRCST study guide (question 42). Original question, not an official exam item.

Question 8Easy

Which of the following correctly lists the six links in the chain of infection?

Show answer and explanation

Correct answer: B. Infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, susceptible host

The six links in the chain of infection are infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, and susceptible host. Other options omit or misstate key links.

From practice test 8 of our CRCST study guide (question 104). Original question, not an official exam item.

Question 9Easy

Which of the following correctly identifies Candida and Aspergillus?

Show answer and explanation

Correct answer: C. Fungi that can cause contamination in sterile processing

Candida (yeast) and Aspergillus (mold) are fungi relevant in sterile processing because they can contaminate sterile supplies if environmental controls fail. They are not bacteria, viruses, or prions.

From practice test 6 of our CRCST study guide (question 44). Original question, not an official exam item.

Question 10Easy

A technician cleans a surgical instrument before placing it in a sterilizer. What is the primary reason for this cleaning step?

Show answer and explanation

Correct answer: A. To reduce bioburden and enhance sterilization efficacy

Cleaning reduces the number of microorganisms (bioburden) and removes organic matter that can protect microbes. Sterilization is more reliable when the instrument is clean.

From practice test 6 of our CRCST study guide (question 16). Original question, not an official exam item.

Question 11Hard

During a sterile setup, a surgical instrument pack is opened and placed on the mayo stand. If the pack's wrapper is tucked under the edge, leaving a 1-inch border, which statement is true about that border?

Show answer and explanation

Correct answer: C. The 1-inch border is considered contaminated because it is in contact with the unsterile surface

In sterile technique, a 1-inch border of a sterile field is considered contaminated due to contact with the unsterile surface. This rule ensures only truly sterile areas are used. The border is not considered sterile even if untouched.

From practice test 4 of our CRCST study guide (question 65). Original question, not an official exam item.

Question 12Hard

A technician is cleaning instruments used on a patient with Clostridium difficile infection. The technician uses an alcohol-based hand rub after removing gloves. Which of the following is the correct critique of this action?

Show answer and explanation

Correct answer: B. The technician should have washed with soap and water because alcohol does not kill spores.

Alcohol-based rubs are ineffective against bacterial spores such as those of Clostridium difficile. Soap and water is required to physically remove spores from the skin. Alcohol rub is not preferred for spore-forming organisms.

From practice test 6 of our CRCST study guide (question 19). Original question, not an official exam item.

Question 13Easy

Which part of a sterile surgical gown is considered unsterile?

Show answer and explanation

Correct answer: D. The back of the gown.

The back of a sterile gown is not considered sterile because it cannot be kept in view and may contact unsterile surfaces.

From practice test 2 of our CRCST study guide (question 122). Original question, not an official exam item.

Question 14Hard

A surgical instrument set is received with a note that it was used on a patient suspected of having Creutzfeldt-Jakob disease. What should be done immediately?

Show answer and explanation

Correct answer: C. Quarantine the set and check manufacturer's instructions for special prion protocol

Prion cases require quarantine until a special protocol (e.g., prolonged autoclaving at 134°C for 18 minutes or 1N NaOH) is completed. Standard processing is inadequate. Manufacturer's instructions must guide the specific steps.

From practice test 6 of our CRCST study guide (question 68). Original question, not an official exam item.

Question 15Hard

Which of the following best explains how performing hand hygiene with an alcohol-based rub before donning sterile gloves breaks the chain of infection?

Show answer and explanation

Correct answer: B. It breaks the chain at the reservoir, portal of exit, mode of transmission, and portal of entry.

Hand hygiene with an alcohol-based rub reduces transient microorganisms on the hands, thereby breaking the chain at the reservoir (hands), portal of exit (hands), mode of transmission (contact), and portal of entry (hands to mucous membranes or patient). No single-link option fully captures its multifaceted effect.

From practice test 6 of our CRCST study guide (question 73). Original question, not an official exam item.

Question 16Easy

Which of the following correctly lists all six links in the chain of infection?

Show answer and explanation

Correct answer: A. Infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, susceptible host

The six links of the chain of infection are infectious agent, reservoir, portal of exit, mode of transmission, portal of entry, and susceptible host, in that sequence. The other options either use incorrect terms or list subcategories of a single link.

From practice test 5 of our CRCST study guide (question 52). Original question, not an official exam item.

Question 17Medium

A central service technician is reprocessing a flexible endoscope that has been used on intact mucous membranes. According to the Spaulding classification, what is the minimum level of disinfection required?

Show answer and explanation

Correct answer: B. High-level disinfection

Items contacting intact mucous membranes are semicritical and require high-level disinfection, which kills all microorganisms except high numbers of bacterial spores. Sterilization (D) is not required for semicritical items, and low- or intermediate-level disinfection (A, B) would not eliminate mycobacteria or non-enveloped viruses.

From practice test 3 of our CRCST study guide (question 2). Original question, not an official exam item.

Question 18Hard

In a central service department, a technician must transport a set of sterilized instruments back to the decontamination area to retrieve a forgotten item. Which of the following best describes the primary risk associated with this action?

Show answer and explanation

Correct answer: C. The one-way workflow is violated, potentially allowing indirect contact transmission to the patient

The one-way workflow from dirty to clean prevents indirect contact transmission, where contaminated surfaces or items transmit pathogens. Returning sterilized items to the decontamination area breaches this workflow, making them potential vehicles for indirect transmission to the patient.

From practice test 5 of our CRCST study guide (question 139). Original question, not an official exam item.

Question 19Hard

A contaminated laparoscope touches the sterile peritoneum during a surgical procedure. This event directly represents which link in the chain of infection?

Show answer and explanation

Correct answer: D. Mode of transmission (indirect contact)

The contaminated instrument serves as an intermediate object transferring pathogens to a new host, which is indirect contact transmission. The reservoir is the instrument itself, the portal of exit is the instrument's surface, and the susceptible host is the patient, but the event illustrates the transmission mode.

From practice test 8 of our CRCST study guide (question 17). Original question, not an official exam item.

Question 20Easy

Which feature of a decontamination pass-through window ensures a one-way workflow from dirty to clean?

Show answer and explanation

Correct answer: D. An interlock system that prevents opening the clean-side door until the dirty-side door is closed.

The interlock physically prevents both doors from being open simultaneously, maintaining separation between the dirty and clean areas. This enforces the one-way flow and prevents cross-contamination.

From practice test 8 of our CRCST study guide (question 54). Original question, not an official exam item.

0 of 20 answered. Your result shows each area against our study target.

Want more mixed questions? Go back to the CRCST practice test hub.

Want the full CRCST preparation?

These questions come from our CRCST study guide: full-length practice tests with every answer explained, flashcards, an AI study tutor and the audiobook.